Built to CE, UL or CSA standards
High-accuracy and easy to use blower balancing machines for axial, centrifugal, mixed-flow and squirrel cage blowers, in horizontal, vertical or non-rotating formats. Every machine is proved to ISO 21940-21 before it ships and is built to CE, UL or CSA standards. Engineered for robustness, backed by up to a 3-year warranty, with installation and operator training included.

Overview
Built for the impeller.
Blower balancers are available as horizontal, vertical or static (non-rotating) machines, depending on the blower type and size. Blower wheels on their own shaft, or on a mandrel, run on a horizontal machine; wheels with a central bore suit a vertical machine; large or windage-sensitive wheels can be balanced non-rotating. For fans and fan assemblies, see our fan balancing machines.
Correction is usually carried out manually, with operators adding clips, welding weights, or grinding and trimming material to remove mass.
Most machines are supplied for manual operation, but where production volumes demand it, some automation is possible.
Tooling is tailored to the type of blower. Some blowers are mounted on their own shafts, while others need mandrels or arbors. Blower wheels with a bore can be clamped quickly on a vertical machine with automatic chucks, making changeover fast and efficient.
Applications
Where it works.
Key features
Accurate. Robust. Simple.
Every machine is proved to ISO 21940-21 before it ships.
Engineered for continuous industrial use
Easy setup, fast changeover.
Industry leading on new machines.
Measuring system
Measure, correct, certify.
Our fifth-generation measuring system: dedicated electronics that measure unbalance with extreme accuracy, connected over Ethernet to the UltraX balancing software.
01 / 06
Each correction plane has its own polar display, with the unbalance amount, angle and correction in large, easy-to-read figures. During correction, every hole appears with its depth and angle and turns green once drilled.
The real UltraX software balancing a demo rotor: measure, drill, re-measure.
Specifications
The numbers.
| Model | H1.6B | H5B | H10B | H16B | H50B | H100B | H160B | H300B | H500B | H1000B | H2000B | H3000B | H5000B | H7500B |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Maximum rotor weight (kg) | 1.6 | 5 | 10 | 16 | 50 | 100 | 160 | 300 | 500 | 1000 | 2000 | 3000 | 5000 | 7500 |
| Maximum rotor diameter (mm) | 260 | 300 | 300 | 360 | 700 | 800 | 1000 | 1200 | 1500 | 1600 | 1600 | 1600 | 2100 | 2100 |
| Rotor journal range (mm) | 3-15 | 3-15 | 5-20 | 5-25 | 6-30 | 8-50 | 9-70 | 10-70 | 10-140 | 15-120 | 15-120 | 25-180 | 25-180 | 40-220 |
| Increased journal range (mm) | 15-25 | 15-25 | 20-40 | 22-50 | 30-70 | 50-100 | 70-140 | 70-140 | 70-140 | 100-220 | 120-240 | 180-280 | 180-380 | 220-380 |
| Minimum achievable residual unbalance gmm/kg | 0.1 | 0.1 | 0.1 | 0.2 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
| URR (%) | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 |
| Standard bed length (mm) | 450 | 450 | 450 | 500 | 700 | 700 | 1760 | 1500 | 1500 | 2000 | 2000 | 3000 | 3000 | 4000 |
| Maximum distance between two supports (mm) | 400 | 400 | 400 | 450 | 450 | 450 | 1050 | 1350 | 1350 | 1740 | 1740 | 2650 | 2550 | 3550 |
| The minimum distance between the driving device and the two supporting swing frames (mm) | 40 | 40 | 40 | 50 | 90 | 90 | 130 | 150 | 150 | 260 | 260 | 350 | 450 | 450 |
| Drive power (kW) | 0.25 | 0.25 | 0.25 | 0.37 | 0.75 | 0.75 | 1.5 | 3 | 3 | 4.5 | 5.5 | 5.5 | 7.5 | 7.5 |
| Drive diameter at the belt drive (mm) | 10-80 | 10-120 | 10-220 | 10-150 | 10-220 | 10-220 | 20-350 | 20-350 | 20-450 | 30-600 | 30-600 | 30-800 | 20-1000 | 50-1000 |
| Speed range (rpm) | 800-4500 | 800-4500 | 800-4500 | 800-4500 | 300-3500 | 300-3500 | 300-3500 | 300-3800 | 300-3800 | 300-3500 | 300-2500 | 300-2500 | 300-2500 | 300-2500 |
Scroll sideways for all 14 models
| Model | H160E | H300E | H500E | H1000E | H2000E | H3000E | H5000E | H7500E | H10000E |
|---|---|---|---|---|---|---|---|---|---|
| Maximum rotor weight (kg) | 160 | 300 | 500 | 1000 | 2000 | 3000 | 5000 | 7500 | 10000 |
| Maximum rotor diameter (mm) | 1500 | 1600 | 1600 | 2100 | 2100 | 2400 | 2400 | 2800 | 3600 |
| Rotor journal range (mm) | 15-70 | 15-70 | 20-140 | 25-140 | 25-180 | 40-180 | 40-180 | 40-180 | 50-240 |
| Increased journal range (mm) | 70-140 | 70-140 | 120-180 | 120-220 | 180-280 | 180-280 | 180-380 | 180-380 | 220-380 |
| Minimum achievable residual unbalance gmm/kg | 0.5 | 0.5 | 0.5 | 1 | 1 | 1 | 1 | 1 | 1 |
| URR (%) | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 |
| Permanent calibration speed limit value (10⁶kg/min²) | 7800 | ||||||||
| Standard bed length (mm) | 3000 | 3000 | 3000 | 3000 | 3000 | 4000 | 4000 | 4000 | 4000 |
| The maximum distance from the flange end face of the universal joint to the right support swing frame (mm) | 1750 | 1750 | 1750 | 1550 | 1550 | 2350 | 2350 | 3300 | 3500 |
| Minimum distance from the center of the supporting swing frame (mm) | 90 | 90 | 90 | 90 | 110 | 110 | 130 | 240 | 500 |
| Drive power (kW) | 3 | 3 | 4.5 | 5.5 | 5.5 | 7.5 | 15 | 22 | 55 |
| Speed range (rpm) | 300-2000 | 300-2000 | 300-2000 | 300-2000 | 300-2000 | 300-2000 | 300-2000 | 300-2000 | 300-2000 |
Scroll sideways for all 11 models
Non-standard specifications available.
| Model | V1.5 | V5 | V16 | V42 | V65 | V100 | V200 | V300 |
|---|---|---|---|---|---|---|---|---|
| Maximum rotor weight - including tooling (kg) | 1.5 | 5 | 16 | 42 | 65 | 100 | 200 | 300 |
| Maximum rotor diameter (mm) | 120 | 280 | 500 | 500 | 700 | 1000 | 1200 | 1500 |
| Maximum rotor thickness (mm) | 60 | 70 | 160 | 160 | 200 | 250 | 250 | 250 |
| Minimum achievable residual unbalance gmm/kg | 0.5 | 0.5 | 1 | 1 | 3 | 5 | 5 | 5 |
| URR (%) | 95 | 95 | 95 | 95 | 95 | 95 | 95 | 95 |
| Drive power (kW) | 0.2 | 0.4 | 1.5 | 1.5 | 3 | 3 | 4.5 | 5.5 |
| Balance speed (rpm) — max balance speed presettable | 3000 | 2400 | 1250 | 1250 | 960 | 760 | 760 | 550 |
Scroll sideways for all 8 models
Non-standard specifications available.
Machines for rotors over 10,000 kg (22,000 lbs) are built to order. Ask us about your rotor.
Why Balance & Test
Service that delivers.
Industry leading on new machines.
Installation and operator training included as standard.
Plus local service teams.
Head office and service center in Bristol, UK; service and support in Ann Arbor, Michigan; engineering, manufacturing and support in Spain; sales and support in Germany.
Balancing machines and all our equipment are built to CE, UL or CSA standards, to suit your market.
We service and calibrate balancing machines from any manufacturer.
FAQ
All blower balancers are built to CE, UL or CSA standards to suit your market, and every machine is proved to ISO 21940-21 before shipment.
It depends on the blower. Wheels on their own shaft, or on a mandrel, run on a horizontal machine. Wheels with a central bore suit a vertical machine, where automatic chucks clamp them quickly for fast changeover. Large or windage-sensitive wheels can be balanced non-rotating. Send us the part details and we will configure the right machine for your needs.
Correction is usually carried out manually, with operators adding clips, welding weights, or grinding and trimming material to remove mass. Most machines are supplied for manual operation, but where production volumes demand it, some automation is possible. The built-in ISO calculator works out the tolerance, and balance certificates can be printed directly from the software.
Yes. Installation and operator training are included as standard, and every machine is backed by up to a 3-year warranty. Support comes from our head office and service center in Bristol, UK, our service and support office in Ann Arbor, Michigan, and our teams in Spain and Germany, with remote support and local service teams. We also service and calibrate balancing machines from any manufacturer, so existing machines on site can be covered too.
Related machines
Also worth a look.
Balancing
Specialist manual fan balancers designed for accuracy, repeatability, and ease of use. Engineered for robustness, backed by up to a 3-year…
View fan balancers →Balancing
Highly flexible balancers for all configurations of fan and pump impeller. Engineered for robustness, backed by up to a 3-year…
View impeller balancers →Guide
What G 6.3 and G 2.5 mean, and how to work out the tolerance.
Read the guide →Ready to balance better?
We’ll configure the right blower balancing machine for your technical needs and budget.